Please see error messages below: Listing first from bottom of this page. I can see from the events that the drive failed an attempt to recovery was started but failed. This drive is from a RAID 5 set hot swappable. Is it just a case of replacing the drive and the disk set regenerates?
Event Type: Error
Event Source: Storage Agents
Event Category: Events
Event ID: 1216
Date: 23/10/2006
Time: 6:51:25 AM
User: N/A
Computer: PERFP01
Description:
Drive Array Physical Drive Status Change. The physical drive in Slot 2, SCSI Port 1 Drive 1 with serial number "A2A1P4402KAP0418", has a new status of 3.
(Drive status values: 1=other, 2=ok, 3=failed, 4=predictiveFailure)
[SNMP TRAP: 3046 in CPQIDA.MIB]
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
Event Type: Error
Event Source: CPQCISSE
Event Category: None
Event ID: 24597
Date: 23/10/2006
Time: 6:51:18 AM
User: N/A
Computer: PERFP01
Description:
Physical Drive on DEVICE ID 1 on Port 1 of
Array Controller in slot 2 has failed.
Failure Code: 0x07.
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
Event Type: Information
Event Source: CPQCISSE
Event Category: None
Event ID: 24598
Date: 23/10/2006
Time: 6:51:18 AM
User: N/A
Computer: PERFP01
Description:
Logical Drive 1 of
Array Controller in slot 2 has changed from status code 0 to status code 3.
Status Codes:
0 = OK
1 = FAILED
2 = NOT CONFIGURED
3 = INTERIM RECOVERY MODE
4 = READY FOR RECOVERY
5 = RECOVERING
6 = WRONG PHYSICAL DRIVE REPLACED
7 = PHYSICAL DRIVE NOT PROPERLY CONNECTED
8 = HARDWARE IS OVERHEATING
9 = HARDWARE HAS OVERHEATED
10 = EXPANDING
11 = NOT YET AVAILABLE
12 = QUEUED FOR EXPANSION
13 = UNKNOWN
Data:
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
Event Type: Warning
Event Source: Storage Agents
Event Category: Events
Event ID: 1200
Date: 23/10/2006
Time: 6:51:25 AM
User: N/A
Computer: PERFP01
Description:
Drive Array Logical Drive Status Change. Logical drive number 1 on the array controller in Slot 2 has a new status of 5.
(Logical Drive status values: 1=other, 2=ok, 3=failed, 4=unconfigured, 5=recovering, 6=readyForRebuild, 7=rebuilding, 8=wrongDrive, 9=badConnect, 10=overheating, 11=shutdown, 12=expanding, 13=notAvailable, 14=queuedForExpansion)
[SNMP TRAP: 3034 in CPQIDA.MIB]
Data:
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
Event Type: Error
Event Source: Storage Agents
Event Category: Events
Event ID: 1216
Date: 23/10/2006
Time: 6:51:25 AM
User: N/A
Computer: PERFP01
Description:
Drive Array Physical Drive Status Change. The physical drive in Slot 2, SCSI Port 1 Drive 1 with serial number "A2A1P4402KAP0418", has a new status of 3.
(Drive status values: 1=other, 2=ok, 3=failed, 4=predictiveFailure)
[SNMP TRAP: 3046 in CPQIDA.MIB]
Data: