Please see error messages below: Listing first from bottom of this page. I can see from the events that the drive failed an attempt to recovery was started but failed. This drive is from a RAID 5 set hot swappable. Is it just a case of replacing the drive and the disk set regenerates?

 

 

Event Type:      Error

Event Source:      Storage Agents

Event Category:      Events

Event ID:      1216

Date:            23/10/2006

Time:            6:51:25 AM

User:            N/A

Computer:      PERFP01

Description:

Drive Array Physical Drive Status Change.  The physical drive in Slot 2, SCSI Port 1 Drive 1 with serial number "A2A1P4402KAP0418", has a new status of 3.

(Drive status values: 1=other, 2=ok, 3=failed, 4=predictiveFailure)

[SNMP TRAP: 3046 in CPQIDA.MIB]

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>

Event Type:      Error

Event Source:      CPQCISSE

Event Category:      None

Event ID:      24597

Date:            23/10/2006

Time:            6:51:18 AM

User:            N/A

Computer:      PERFP01

Description:

Physical Drive on DEVICE ID 1 on Port 1 of

Array Controller  in slot 2 has failed.

Failure Code: 0x07.

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>

Event Type:      Information

Event Source:      CPQCISSE

Event Category:      None

Event ID:      24598

Date:            23/10/2006

Time:            6:51:18 AM

User:            N/A

Computer:      PERFP01

Description:

Logical Drive 1 of

Array Controller  in slot 2 has changed from status code 0 to status code 3.

Status Codes:

0  = OK

1  = FAILED

2  = NOT CONFIGURED

3  = INTERIM RECOVERY MODE

4  = READY FOR RECOVERY

5  = RECOVERING

6  = WRONG PHYSICAL DRIVE REPLACED

7  = PHYSICAL DRIVE NOT PROPERLY CONNECTED

8  = HARDWARE IS OVERHEATING

9  = HARDWARE HAS OVERHEATED

10 = EXPANDING

11 = NOT YET AVAILABLE

12 = QUEUED FOR EXPANSION

13 = UNKNOWN

Data:

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>

Event Type:      Warning

Event Source:      Storage Agents

Event Category:      Events

Event ID:      1200

Date:            23/10/2006

Time:            6:51:25 AM

User:            N/A

Computer:      PERFP01

Description:

Drive Array Logical Drive Status Change.  Logical drive number 1 on the array controller in Slot 2 has a new status of 5.

(Logical Drive status values: 1=other, 2=ok, 3=failed, 4=unconfigured, 5=recovering, 6=readyForRebuild, 7=rebuilding, 8=wrongDrive, 9=badConnect, 10=overheating, 11=shutdown, 12=expanding, 13=notAvailable, 14=queuedForExpansion)

[SNMP TRAP: 3034 in CPQIDA.MIB]

Data:

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>

Event Type:      Error

Event Source:      Storage Agents

Event Category:      Events

Event ID:      1216

Date:            23/10/2006

Time:            6:51:25 AM

User:            N/A

Computer:      PERFP01

Description:

Drive Array Physical Drive Status Change.  The physical drive in Slot 2, SCSI Port 1 Drive 1 with serial number "A2A1P4402KAP0418", has a new status of 3.

(Drive status values: 1=other, 2=ok, 3=failed, 4=predictiveFailure)

[SNMP TRAP: 3046 in CPQIDA.MIB]

Data: